OGS NODC's ERDDAP
Easier access to OGS's data
   
Brought to you by NODC
By downloading a resource, you agree to OGS copyright and data policy    

ERDDAP > tabledap > Data Access Form ?

Dataset Title:  MAMBO1 timeSeries, NRT in situ Observations Subscribe RSS
Institution:  National Institute of Oceanography and Applied Geophysics - OGS, Division of Oceanography   (Dataset ID: MAMBO1_TS)
Information:  Summary ? | License ? | FGDC | ISO 19115 | Metadata | Background | Make a graph
 
Variable ?   Optional
Constraint #1 ?
Optional
Constraint #2 ?
   Minimum ?
 
   Maximum ?
 
 time (UTC) ?          2021-01-01T00:00:00Z    
  < slider >
 latitude (degrees_north) ?          41.5277    41.5277
  < slider >
 longitude (degrees_east) ?          18.0824167    18.0824167
  < slider >
 depth (m) ?          -5.0    1185.0
  < slider >
 WDIR (Degrees) ?              
 WDIR_QC ?              
 WSPD (Metres per second) ?              
 WSPD_QC ?              
 DRYT (Degrees Celsius) ?              
 DRYT_QC ?              
 ATMS (Millibars) ?              
 ATMS_QC ?              
 RELH (relative humidity, Percent) ?              
 RELH_QC ?              
 HEAD (Degrees) ?              
 HEAD_QC ?              
 EWSB (Metres per second) ?              
 EWSB_QC (quality_flag) ?              
 GSPD (Metres per second) ?              
 GSPD_QC (gust wind speed quality flag) ?              
 GDIR (Degrees) ?              
 GDIR_QC ?              
 CHUM (Parts per million) ?              
 CHUM_QC (quality_flag) ?              
 ACO2 (Parts per million) ?              
 ACO2_QC (quality_flag) ?              
 PCOW (Parts per million) ?              
 PCOW_QC ?              
 TMES_1 (Millibars) ?              
 TMES_1_QC (quality_flag) ?              
 TEMP_1 (Degrees Celsius) ?              
 TEMP_1_QC ?              
 CNDC_1 (Siemens per metre) ?              
 CNDC_1_QC ?              
 PRES_1 (sea pressure, Decibars) ?              
 PRES_1_QC (sea pressure quality flag) ?              
 DOXY_1 (Millilitres per litre) ?              
 DOXY_1_QC (dissolved oxygen quality flag) ?              
 PSAL_1 (Dimensionless) ?              
 PSAL_1_QC ?              
 SVEL_1 (Metres per second) ?              
 SVEL_1_QC (sound velocity quality flag) ?              
 ALKY (total alkalinity, pH units) ?              
 ALKY_QC (total alkalinity quality flag) ?              
 PHPH_1 (ph, pH units) ?              
 PHPH_1_QC (ph quality flag) ?              
 TEMP_2 (Degrees Celsius) ?              
 TEMP_2_QC ?              
 TMES_2 (Degrees Celsius) ?              
 TMES_2_QC (quality_flag) ?              
 TEMP_3 (Degrees Celsius) ?              
 TEMP_3_QC ?              
 CNDC_2 (Siemens per metre) ?              
 CNDC_2_QC ?              
 PRES_2 (sea pressure, Decibars) ?              
 PRES_2_QC (sea pressure quality flag) ?              
 DOXY_2 (Millilitres per litre) ?              
 DOXY_2_QC (dissolved oxygen quality flag) ?              
 PHPH_2 (ph, pH units) ?              
 PHPH_2_QC (ph quality flag) ?              
 CPWC (Micrograms per litre) ?              
 CPWC_QC (quality_flag) ?              
 TUR4 (Nephelometric Turbidity Units) ?              
 TUR4_QC (turbidity quality flag) ?              
 VSRW (MicroEinsteins per square metre per second) ?              
 VSRW_QC (quality_flag) ?              
 PSAL_2 (Dimensionless) ?              
 PSAL_2_QC ?              
 SVEL_2 (Metres per second) ?              
 SVEL_2_QC (sound velocity quality flag) ?              
 TEMP_4 (Degrees Celsius) ?              
 TEMP_4_QC ?              
 CNDC_3 (Siemens per metre) ?              
 CNDC_3_QC ?              
 PRES_3 (sea pressure, Decibars) ?              
 PRES_3_QC (sea pressure quality flag) ?              
 DOXY_3 (Millilitres per litre) ?              
 DOXY_3_QC (dissolved oxygen quality flag) ?              
 PSAL_3 (Dimensionless) ?              
 PSAL_3_QC ?              
 SVEL_3 (Metres per second) ?              
 SVEL_3_QC (sound velocity quality flag) ?              
 
Server-side Functions ?
 distinct() ?
? ("Hover here to see a list of options. Click on an option to select it.Hover here to see a list of options. Click on an option to select it.Hover here to see a list of options. Click on an option to select it.Hover here to see a list of options. Click on an option to select it.Hover here to see a list of options. Click on an option to select it.")

File type: (more information)

(Documentation / Bypass this form ? )
 
(Please be patient. It may take a while to get the data.)


 

The Dataset Attribute Structure (.das) for this Dataset

Attributes {
 s {
  time {
    String _CoordinateAxisType "Time";
    Float64 actual_range 1.6094592e+9, NaN;
    String axis "T";
    String cf_role "timeseries_id";
    String ioos_category "Time";
    String long_name "Time";
    String sdn_parameter_name "Elapsed time relative to 1970-01-01T00:00:00Z";
    String sdn_parameter_urn "SDN:P01::ELTMEP01";
    String sdn_uom_name "Seconds";
    String sdn_uom_urn "SDN:P06::UTBB";
    String standard_name "time";
    String time_origin "01-JAN-1970 00:00:00";
    String units "seconds since 1970-01-01T00:00:00Z";
  }
  latitude {
    String _CoordinateAxisType "Lat";
    Float64 actual_range 41.5277, 41.5277;
    String axis "Y";
    String ioos_category "Location";
    String long_name "Latitude";
    String sdn_parameter_name "Latitude north";
    String sdn_parameter_urn "SDN:P01::ALATZZ01";
    String sdn_uom_name "Degrees north";
    String sdn_uom_urn "SDN:P06::DEGN";
    String standard_name "latitude";
    String units "degrees_north";
  }
  longitude {
    String _CoordinateAxisType "Lon";
    Float64 actual_range 18.0824167, 18.0824167;
    String axis "X";
    String ioos_category "Location";
    String long_name "Longitude";
    String sdn_parameter_name "Longitude east";
    String sdn_parameter_urn "SDN:P01::ALONZZ01";
    String sdn_uom_name "Degrees east";
    String sdn_uom_urn "SDN:P06::DEGE";
    String standard_name "longitude";
    String units "degrees_east";
  }
  depth {
    String _CoordinateAxisType "Height";
    String _CoordinateZisPositive "down";
    Float32 actual_range -5.0, 1185.0;
    String axis "Z";
    String ioos_category "Location";
    String long_name "Depth";
    String positive "down";
    String reference "sea_level";
    String sdn_parameter_name "Depth (spatial coordinate) relative to water surface in the water body";
    String sdn_parameter_urn "SDN:P01::ADEPZZ01";
    String sdn_uom_name "Metres";
    String sdn_uom_urn "SDN:P06::ULAA";
    String standard_name "depth";
    String units "m";
  }
  WDIR {
    String ancillary_variables "WDIR_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Wind";
    String long_name "wind from direction relative true north";
    String sdn_parameter_name "Direction (from) of wind relative to True North {wind direction} in the atmosphere";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/EWDAZZ01/";
    String sdn_parameter_urn "SDN:P01::EWDAZZ01";
    String sdn_uom_name "Degrees";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UAAA/";
    String sdn_uom_urn "SDN:P06::UAAA";
    String sensor_manufacturer "R.M. Young";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0037/";
    String sensor_manufacturer_urn "SDN:L35::MAN0037";
    String sensor_model "RM Young 32500 (electronic) magnetic compass";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1327/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL1327";
    String standard_name "wind_from_direction";
    String units "Degrees";
  }
  WDIR_QC {
    Byte _FillValue 127;
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String long_name "wind from direction relative true north quality flag";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  WSPD {
    String ancillary_variables "WSPD_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Wind";
    String long_name "horizontal wind speed";
    String sdn_parameter_name "Speed of wind {wind speed} in the atmosphere";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/EWSBZZ01/";
    String sdn_parameter_urn "SDN:P01::EWSBZZ01";
    String sdn_uom_name "Metres per second";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UVAA/";
    String sdn_uom_urn "SDN:P06::UVAA";
    String sensor_manufacturer "R.M. Young";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0037/";
    String sensor_manufacturer_urn "SDN:L35::MAN0037";
    String sensor_model "RM Young 32500 (electronic) magnetic compass";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1327/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL1327";
    String standard_name "wind_speed";
    String units "Metres per second";
  }
  WSPD_QC {
    Byte _FillValue 127;
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String long_name "horizontal wind speed quality flag";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  DRYT {
    String ancillary_variables "DRYT_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Temperature";
    String long_name "air temperature in dry bulb";
    String sdn_parameter_name "Temperature of the atmosphere";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/CTMPZZ01/";
    String sdn_parameter_urn "SDN:P01::CTMPZZ01";
    String sdn_uom_name "Degrees Celsius";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UPAA/";
    String sdn_uom_urn "SDN:P06::UPAA";
    String sensor_manufacturer "R.M. Young";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0037/";
    String sensor_manufacturer_urn "SDN:L35::MAN0037";
    String sensor_model "RM Young 32500 (electronic) magnetic compass";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1327/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL1327";
    String standard_name "air_temperature";
    String units "Degrees Celsius";
  }
  DRYT_QC {
    Byte _FillValue 127;
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String long_name "air temperature in dry bulb quality flag";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  ATMS {
    String ancillary_variables "ATMS_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Pressure";
    String long_name "atmospheric pressure at sea level";
    String sdn_parameter_name "Pressure (measured variable) exerted by the atmosphere by unknown instrument and correction to sea level";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/CAPAZZ01/";
    String sdn_parameter_urn "SDN:P01::CAPAZZ01";
    String sdn_uom_name "Millibars";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UPBB/";
    String sdn_uom_urn "SDN:P06::UPBB";
    String sensor_manufacturer "R.M. Young";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0037/";
    String sensor_manufacturer_urn "SDN:L35::MAN0037";
    String sensor_model "RM Young 32500 (electronic) magnetic compass";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1327/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL1327";
    String standard_name "air_pressure_at_sea_level";
    String units "Millibars";
  }
  ATMS_QC {
    Byte _FillValue 127;
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String long_name "atmospheric pressure at sea level quality flag";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  RELH {
    String ancillary_variables "RELH_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Meteorology";
    String long_name "relative humidity";
    String sdn_parameter_name "Relative humidity of the atmosphere";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/CRELZZ01/";
    String sdn_parameter_urn "SDN:P01::CRELZZ01";
    String sdn_uom_name "Percent";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UPCT/";
    String sdn_uom_urn "SDN:P06::UPCT";
    String sensor_manufacturer "R.M. Young";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0037/";
    String sensor_manufacturer_urn "SDN:L35::MAN0037";
    String sensor_model "RM Young 32500 (electronic) magnetic compass";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1327/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL1327";
    String standard_name "relative_humidity";
    String units "Percent";
  }
  RELH_QC {
    Byte _FillValue 127;
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String long_name "relative humidity quality flag";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  HEAD {
    String ancillary_variables "HEAD_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Other";
    String long_name "Parameters that describe the displacement of platforms or instruments in space relative to various origins";
    String sdn_parameter_name "Orientation (horizontal relative to magnetic north) of measurement platform {heading} by compass";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/HEADCMMG/";
    String sdn_parameter_urn "SDN:P01::HEADCMMG";
    String sdn_uom_name "Degrees";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UAAA/";
    String sdn_uom_urn "SDN:P06::UAAA";
    String sensor_manufacturer "R.M. Young";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0037/";
    String sensor_manufacturer_urn "SDN:L35::MAN0037";
    String sensor_model "RM Young 32500 (electronic) magnetic compass";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1327/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL1327";
    String standard_name "platform or instrument orientation";
    String units "Degrees";
  }
  HEAD_QC {
    Byte _FillValue 127;
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String long_name "The magnetically-corrected compass direction towards which a structure bearing sensors or sampling devices is pointing. quality flag";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  EWSB {
    String ancillary_variables "EWSB_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Wind";
    String long_name "Parameters quantifying the extent or direction of atmospheric movement. Obvious examples are wind velocity, windspeed and wind direction, but can also include derived parameters such as force, energy, power and power density.";
    String sdn_parameter_name "Speed of wind {wind speed} in the atmosphere by in-situ anemometer";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/EWSKSS01/";
    String sdn_parameter_urn "SDN:P01::EWSKSS01";
    String sdn_uom_name "Metres per second";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UVAA/";
    String sdn_uom_urn "SDN:P06::UVAA";
    String sensor_manufacturer "R.M. Young";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0037/";
    String sensor_manufacturer_urn "SDN:L35::MAN0037";
    String sensor_model "RM Young 32500 (electronic) magnetic compass";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1327/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL1327";
    String standard_name "wind strength and direction";
    String units "Metres per second";
  }
  EWSB_QC {
    Byte _FillValue 127;
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  GSPD {
    String ancillary_variables "GSPD_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Wind";
    String long_name "gust wind speed";
    String sdn_parameter_name "Speed of wind (gust) {wind speed} in the atmosphere";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/EGTSZZ01/";
    String sdn_parameter_urn "SDN:P01::EGTSZZ01";
    String sdn_uom_name "Metres per second";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UVAA/";
    String sdn_uom_urn "SDN:P06::UVAA";
    String sensor_manufacturer "R.M. Young";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0037/";
    String sensor_manufacturer_urn "SDN:L35::MAN0037";
    String sensor_model "RM Young 32500 (electronic) magnetic compass";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1327/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL1327";
    String standard_name "wind_speed_of_gust";
    String units "Metres per second";
  }
  GSPD_QC {
    Byte _FillValue 127;
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String long_name "gust wind speed quality flag";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  GDIR {
    String ancillary_variables "GDIR_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Wind";
    String sdn_parameter_name "Direction (from) of wind (gust) relative to True North {wind direction} in the atmosphere";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/EGTDZZ01/";
    String sdn_parameter_urn "SDN:P01::EGTDZZ01";
    String sdn_uom_name "Degrees";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UAAA/";
    String sdn_uom_urn "SDN:P06::UAAA";
    String sensor_manufacturer "R.M. Young";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0037/";
    String sensor_manufacturer_urn "SDN:L35::MAN0037";
    String sensor_model "RM Young 32500 (electronic) magnetic compass";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1327/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL1327";
    String units "Degrees";
  }
  GDIR_QC {
    Byte _FillValue 127;
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String long_name "The direction from which a gust event (generally regarded as an increase over sustained speed of more than 5 m/s lasting less than 20 seconds) is blowing quality flag";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  CHUM {
    String ancillary_variables "CHUM_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Pressure";
    String long_name "Parameters that either quantify the water content of moist air or are specifically used in its determination (eg wet bulb air temperature)";
    String sdn_parameter_name "Partial pressure of water vapour in the atmosphere";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/CPVPZZ01/";
    String sdn_parameter_urn "SDN:P01::CPVPZZ01";
    String sdn_uom_name "Parts per million";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UPPM/";
    String sdn_uom_urn "SDN:P06::UPPM";
    String sensor_manufacturer "LI-COR, Inc.";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0200/";
    String sensor_manufacturer_urn "SDN:L35::MAN0200";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL2021/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL2021";
    String standard_name "atmospheric humidity";
    String units "Parts per million";
  }
  CHUM_QC {
    Byte _FillValue 127;
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  ACO2 {
    String ancillary_variables "ACO2_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Other";
    String long_name "CO and CO2 concentration parameters in any phase of the atmosphere (but usuall the gaseous phase). Includes pCO2.";
    String sdn_parameter_name "Mole fraction in dry air of carbon dioxide {CO2 CAS 124-38-9} {xCO2} in the atmosphere";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/XCO2DRAT/";
    String sdn_parameter_urn "SDN:P01::XCO2DRAT";
    String sdn_uom_name "Parts per million";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UPPM/";
    String sdn_uom_urn "SDN:P06::UPPM";
    String sensor_manufacturer "LI-COR, Inc.";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0200/";
    String sensor_manufacturer_urn "SDN:L35::MAN0200";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL2021/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL2021";
    String standard_name "carbon monoxide and dioxide concentrations in the atmosphere";
    String units "Parts per million";
  }
  ACO2_QC {
    Byte _FillValue 127;
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  PCOW {
    String ancillary_variables "PCOW_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Other";
    String sdn_parameter_name "Partial pressure of carbon dioxide {CO2 CAS 124-38-9} {pCO2} in the water body by equilibration with air, drying and infra-red gas analysis";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/PCO2EG01/";
    String sdn_parameter_urn "SDN:P01::PCO2EG01";
    String sdn_uom_name "Parts per million";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UPPM/";
    String sdn_uom_urn "SDN:P06::UPPM";
    String sensor_manufacturer "Pro Oceanus";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0033/";
    String sensor_manufacturer_urn "SDN:L35::MAN0033";
    String sensor_model "Pro-Oceanus CO2-Pro Atmosphere pCO2 sensor";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1780/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL1780";
    String units "Parts per million";
  }
  PCOW_QC {
    Byte _FillValue 127;
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String long_name "The partial pressure of carbon dioxide in the water body by equilibration with air quality flag";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  TMES_1 {
    String ancillary_variables "TMES_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Other";
    String long_name "Data parameters that carry information relating to a measured parameter such as measurement temperatures, integration depths, quantities sampled and incubation durations";
    String sdn_parameter_name "Pressure (in measurement loop for equilibrated marine sample)";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/PRES00EQ/";
    String sdn_parameter_urn "SDN:P01::PRES00EQ";
    String sdn_uom_name "Millibars";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UPBB/";
    String sdn_uom_urn "SDN:P06::UPBB";
    String sensor_manufacturer "Pro Oceanus";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0033/";
    String sensor_manufacturer_urn "SDN:L35::MAN0033";
    String sensor_model "Pro-Oceanus CO2-Pro Atmosphere pCO2 sensor";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1780/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL1780";
    String standard_name "metadata parameters";
    String units "Millibars";
  }
  TMES_1_QC {
    Byte _FillValue 127;
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  TEMP_1 {
    String ancillary_variables "TEMP_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Temperature";
    String long_name "sea potential temperature";
    String sdn_parameter_name "Temperature of the water body";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/TEMPPR01/";
    String sdn_parameter_urn "SDN:P01::TEMPPR01";
    String sdn_uom_name "Degrees Celsius";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UPAA/";
    String sdn_uom_urn "SDN:P06::UPAA";
    String sensor_manufacturer "Sea-Bird Scientific";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0013/";
    String sensor_manufacturer_urn "SDN:L35::MAN0013";
    String sensor_model "Sea-Bird SBE 37 MicroCat SMP-CTP-ODO (submersible) CTD sensor";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1459/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL1459";
    String standard_name "sea_water_potential_temperature";
    String units "Degrees Celsius";
  }
  TEMP_1_QC {
    Byte _FillValue 127;
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String long_name "sea potential temperature quality flag";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  CNDC_1 {
    String ancillary_variables "CNDC_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Other";
    String long_name "electrical conductivity";
    String sdn_parameter_name "Electrical conductivity of the water body";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/CNDCZZ01/";
    String sdn_parameter_urn "SDN:P01::CNDCZZ01";
    String sdn_uom_name "Siemens per metre";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UECA/";
    String sdn_uom_urn "SDN:P06::UECA";
    String sensor_manufacturer "Sea-Bird Scientific";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0013/";
    String sensor_manufacturer_urn "SDN:L35::MAN0013";
    String sensor_model "Sea-Bird SBE 37 MicroCat SMP-CTP-ODO (submersible) CTD sensor";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1459/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL1459";
    String standard_name "sea_water_electrical_conductivity";
    String units "Siemens per metre";
  }
  CNDC_1_QC {
    Byte _FillValue 127;
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String long_name "electrical conductivity quality flag";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  PRES_1 {
    String ancillary_variables "PRES_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Pressure";
    String long_name "sea pressure";
    String sdn_parameter_name "Pressure (spatial coordinate) exerted by the water body by profiling pressure sensor and correction to read zero at sea level";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/PRESPR01/";
    String sdn_parameter_urn "SDN:P01::PRESPR01";
    String sdn_uom_name "Decibars";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UPDB/";
    String sdn_uom_urn "SDN:P06::UPDB";
    String sensor_manufacturer "Sea-Bird Scientific";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0013/";
    String sensor_manufacturer_urn "SDN:L35::MAN0013";
    String sensor_model "Sea-Bird SBE 37 MicroCat SMP-CTP-ODO (submersible) CTD sensor";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1459/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL1459";
    String standard_name "sea_water_pressure";
    String units "Decibars";
  }
  PRES_1_QC {
    Byte _FillValue 127;
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String long_name "sea pressure quality flag";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  DOXY_1 {
    String ancillary_variables "DOXY_1_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Other";
    String long_name "dissolved oxygen";
    String sdn_parameter_name "Concentration of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] by in-situ sensor";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/DOXYZZ01/";
    String sdn_parameter_urn "SDN:P01::DOXYZZ01";
    String sdn_uom_name "Millilitres per litre";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UMLL/";
    String sdn_uom_urn "SDN:P06::UMLL";
    String sensor_manufacturer "Sea-Bird Scientific";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0013/";
    String sensor_manufacturer_urn "SDN:L35::MAN0013";
    String sensor_model "Sea-Bird SBE 37 MicroCat SMP-CTP-ODO (submersible) CTD sensor";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1459/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL1459";
    String standard_name "mole_concentration_of_dissolved_molecular_oxygen_in_sea_water";
    String units "Millilitres per litre";
  }
  DOXY_1_QC {
    Byte _FillValue 127;
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String long_name "dissolved oxygen quality flag";
    Byte missing_value 0;
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  PSAL_1 {
    String ancillary_variables "PSAL_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Other";
    String long_name "practical salinity";
    String sdn_parameter_name "Salinity of the water body by CTD";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/SSALST01/";
    String sdn_parameter_urn "SDN:P01::SSALST01";
    String sdn_uom_name "Dimensionless";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UUUU/";
    String sdn_uom_urn "SDN:P06::UUUU";
    String sensor_manufacturer "Sea-Bird Scientific";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0013/";
    String sensor_manufacturer_urn "SDN:L35::MAN0013";
    String sensor_model "Sea-Bird SBE 37 MicroCat SMP-CTP-ODO (submersible) CTD sensor";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1459/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL1459";
    String standard_name "sea_water_salinity";
    String units "Dimensionless";
  }
  PSAL_1_QC {
    Byte _FillValue 127;
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String long_name "practical salinity quality flag";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  SVEL_1 {
    String ancillary_variables "SVEL_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Other";
    String long_name "sound velocity";
    String sdn_parameter_name "Sound velocity in the water body by computation from temperature and salinity by unspecified algorithm";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/SVELCV01/";
    String sdn_parameter_urn "SDN:P01::SVELCV01";
    String sdn_uom_name "Metres per second";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UVAA/";
    String sdn_uom_urn "SDN:P06::UVAA";
    String sensor_manufacturer "Sea-Bird Scientific";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0013/";
    String sensor_manufacturer_urn "SDN:L35::MAN0013";
    String sensor_model "Sea-Bird SBE 37 MicroCat SMP-CTP-ODO (submersible) CTD sensor";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1459/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL1459";
    String standard_name "speed_of_sound_in_sea_water";
    String units "Metres per second";
  }
  SVEL_1_QC {
    Byte _FillValue 127;
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String long_name "sound velocity quality flag";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  ALKY {
    String ancillary_variables "ALKY_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Other";
    String long_name "total alkalinity";
    String sdn_parameter_name "pH (total scale) {pH[T]} of the water body by ion sensitive field-effect transistor (ISFET) sensor (external counter electrode) and manufacturer's calibration applied";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/PHXXFE03/";
    String sdn_parameter_urn "SDN:P01::PHXXFE03";
    String sdn_uom_name "pH units";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UUPH/";
    String sdn_uom_urn "SDN:P06::UUPH";
    String sensor_manufacturer "Sea-Bird Scientific";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0013/";
    String sensor_manufacturer_urn "SDN:L35::MAN0013";
    String sensor_model "Satlantic SeaFET V2 {Sea-Bird Scientific} (shallow) pH sensor";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1293/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL1293";
    String standard_name "sea_water_alkalinity_expressed_as_mole_equivalent";
    String units "pH units";
  }
  ALKY_QC {
    Byte _FillValue 127;
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String long_name "total alkalinity quality flag";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  PHPH_1 {
    String ancillary_variables "PHPH_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Other";
    String long_name "ph";
    String sdn_parameter_name "pH (total scale) {pH[T]} of the water body by ion sensitive field-effect transistor (ISFET) sensor (internal counter electrode) and manufacturer's calibration applied";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/PHXXFE02/";
    String sdn_parameter_urn "SDN:P01::PHXXFE02";
    String sdn_uom_name "pH units";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UUPH/";
    String sdn_uom_urn "SDN:P06::UUPH";
    String sensor_manufacturer "Sea-Bird Scientific";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0013/";
    String sensor_manufacturer_urn "SDN:L35::MAN0013";
    String sensor_model "Satlantic SeaFET V2 {Sea-Bird Scientific} (shallow) pH sensor";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1293/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL1293";
    String standard_name "sea_water_ph_reported_on_total_scale";
    String units "pH units";
  }
  PHPH_1_QC {
    Byte _FillValue 127;
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String long_name "ph quality flag";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  TEMP_2 {
    String ancillary_variables "TEMP_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Temperature";
    String long_name "sea potential temperature";
    String sdn_parameter_name "Temperature of the water body";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/TEMPPR01/";
    String sdn_parameter_urn "SDN:P01::TEMPPR01";
    String sdn_uom_name "Degrees Celsius";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UPAA/";
    String sdn_uom_urn "SDN:P06::UPAA";
    String sensor_manufacturer "Sea-Bird Scientific";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0013/";
    String sensor_manufacturer_urn "SDN:L35::MAN0013";
    String sensor_model "Satlantic SeaFET V2 {Sea-Bird Scientific} (shallow) pH sensor";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1293/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL1293";
    String standard_name "sea_water_potential_temperature";
    String units "Degrees Celsius";
  }
  TEMP_2_QC {
    Byte _FillValue 127;
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String long_name "sea potential temperature quality flag";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  TMES_2 {
    String ancillary_variables "TMES_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Temperature";
    String long_name "Data parameters that carry information relating to a measured parameter such as measurement temperatures, integration depths, quantities sampled and incubation durations";
    String sdn_parameter_name "Temperature of pH determination";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/PHTXPR01/";
    String sdn_parameter_urn "SDN:P01::PHTXPR01";
    String sdn_uom_name "Degrees Celsius";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UPAA/";
    String sdn_uom_urn "SDN:P06::UPAA";
    String sensor_manufacturer "Sea-Bird Scientific";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0013/";
    String sensor_manufacturer_urn "SDN:L35::MAN0013";
    String sensor_model "Satlantic SeaFET V2 {Sea-Bird Scientific} (shallow) pH sensor";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL1293/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL1293";
    String standard_name "metadata parameters";
    String units "Degrees Celsius";
  }
  TMES_2_QC {
    Byte _FillValue 127;
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  TEMP_3 {
    String ancillary_variables "TEMP_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Temperature";
    String long_name "sea potential temperature";
    String sdn_parameter_name "Temperature of the water body";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/TEMPPR01/";
    String sdn_parameter_urn "SDN:P01::TEMPPR01";
    String sdn_uom_name "Degrees Celsius";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UPAA/";
    String sdn_uom_urn "SDN:P06::UPAA";
    String sensor_manufacturer "Sea-Bird Scientific";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0013/";
    String sensor_manufacturer_urn "SDN:L35::MAN0013";
    String sensor_model "Sea-Bird SBE 16Plus V2 SEACAT C-T Recorder";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL0870/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL0870";
    String standard_name "sea_water_potential_temperature";
    String units "Degrees Celsius";
  }
  TEMP_3_QC {
    Byte _FillValue 127;
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String long_name "sea potential temperature quality flag";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  CNDC_2 {
    String ancillary_variables "CNDC_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Other";
    String long_name "electrical conductivity";
    String sdn_parameter_name "Electrical conductivity of the water body";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/CNDCZZ01/";
    String sdn_parameter_urn "SDN:P01::CNDCZZ01";
    String sdn_uom_name "Siemens per metre";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UECA/";
    String sdn_uom_urn "SDN:P06::UECA";
    String sensor_manufacturer "Sea-Bird Scientific";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0013/";
    String sensor_manufacturer_urn "SDN:L35::MAN0013";
    String sensor_model "Sea-Bird SBE 16Plus V2 SEACAT C-T Recorder";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL0870/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL0870";
    String standard_name "sea_water_electrical_conductivity";
    String units "Siemens per metre";
  }
  CNDC_2_QC {
    Byte _FillValue 127;
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String long_name "electrical conductivity quality flag";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  PRES_2 {
    String ancillary_variables "PRES_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Pressure";
    String long_name "sea pressure";
    String sdn_parameter_name "Pressure (spatial coordinate) exerted by the water body by profiling pressure sensor and correction to read zero at sea level";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/PRESPR01/";
    String sdn_parameter_urn "SDN:P01::PRESPR01";
    String sdn_uom_name "Decibars";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UPDB/";
    String sdn_uom_urn "SDN:P06::UPDB";
    String sensor_manufacturer "Sea-Bird Scientific";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0013/";
    String sensor_manufacturer_urn "SDN:L35::MAN0013";
    String sensor_model "Sea-Bird SBE 16Plus V2 SEACAT C-T Recorder";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL0870/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL0870";
    String standard_name "sea_water_pressure";
    String units "Decibars";
  }
  PRES_2_QC {
    Byte _FillValue 127;
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String long_name "sea pressure quality flag";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  DOXY_2 {
    String ancillary_variables "DOXY_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Other";
    String long_name "dissolved oxygen";
    String sdn_parameter_name "Concentration of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] by in-situ sensor";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/DOXYZZ01/";
    String sdn_parameter_urn "SDN:P01::DOXYZZ01";
    String sdn_uom_name "Millilitres per litre";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UMLL/";
    String sdn_uom_urn "SDN:P06::UMLL";
    String sensor_manufacturer "Sea-Bird Scientific";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0013/";
    String sensor_manufacturer_urn "SDN:L35::MAN0013";
    String sensor_model "Sea-Bird SBE 16Plus V2 SEACAT C-T Recorder";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL0870/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL0870";
    String standard_name "mole_concentration_of_dissolved_molecular_oxygen_in_sea_water";
    String units "Millilitres per litre";
  }
  DOXY_2_QC {
    Byte _FillValue 127;
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String long_name "dissolved oxygen quality flag";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  PHPH_2 {
    String ancillary_variables "PHPH_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Other";
    String long_name "ph";
    String sdn_parameter_name "pH (NBS scale) {pH[NBS]} of the water body by computation";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/PHNBWCAL/";
    String sdn_parameter_urn "SDN:P01::PHNBWCAL";
    String sdn_uom_name "pH units";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UUPH/";
    String sdn_uom_urn "SDN:P06::UUPH";
    String sensor_manufacturer "Sea-Bird Scientific";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0013/";
    String sensor_manufacturer_urn "SDN:L35::MAN0013";
    String sensor_model "Sea-Bird SBE 16Plus V2 SEACAT C-T Recorder";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL0870/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL0870";
    String standard_name "sea_water_ph_reported_on_total_scale";
    String units "pH units";
  }
  PHPH_2_QC {
    Byte _FillValue 127;
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String long_name "ph quality flag";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  CPWC {
    String ancillary_variables "CPWC_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Other";
    String long_name "Includes all variants of chlorophyll expressed in terms of per unit volume, per unit area of any body of fresh or salt water, or as a relative colour index (e.g. PCI). Does not include data expressed per unit mass of SPM.";
    String sdn_parameter_name "Concentration of chlorophyll-a {chl-a CAS 479-61-8} per unit volume of the water body [particulate >unknown phase] by in-situ chlorophyll fluorometer";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/CPHLPR01/";
    String sdn_parameter_urn "SDN:P01::CPHLPR01";
    String sdn_uom_name "Micrograms per litre";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UGPL/";
    String sdn_uom_urn "SDN:P06::UGPL";
    String sensor_manufacturer "Sea-Bird Scientific";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0013/";
    String sensor_manufacturer_urn "SDN:L35::MAN0013";
    String sensor_model "Sea-Bird SBE 16Plus V2 SEACAT C-T Recorder";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL0870/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL0870";
    String standard_name "chlorophyll pigment concentrations in water bodies";
    String units "Micrograms per litre";
  }
  CPWC_QC {
    Byte _FillValue 127;
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  TUR4 {
    String ancillary_variables "TUR4_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Other";
    String long_name "turbidity";
    String sdn_parameter_name "Turbidity of water in the water body by in-situ optical backscatter measurement and laboratory calibration against formazin";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/TURBXXXX/";
    String sdn_parameter_urn "SDN:P01::TURBXXXX";
    String sdn_uom_name "Nephelometric Turbidity Units";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/USTU/";
    String sdn_uom_urn "SDN:P06::USTU";
    String sensor_manufacturer "Sea-Bird Scientific";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0013/";
    String sensor_manufacturer_urn "SDN:L35::MAN0013";
    String sensor_model "Sea-Bird SBE 16Plus V2 SEACAT C-T Recorder";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL0870/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL0870";
    String standard_name "sea_water_turbidity";
    String units "Nephelometric Turbidity Units";
  }
  TUR4_QC {
    Byte _FillValue 127;
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String long_name "turbidity quality flag";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  VSRW {
    String ancillary_variables "VSRW_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Other";
    String long_name "Includes measurements at discrete wavelengths and PAR integrated values, measurements as photon and energy fluxes.";
    String sdn_parameter_name "Downwelling vector irradiance as photons of electromagnetic radiation (PAR wavelengths) in the water body by cosine-collector radiometer";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/IRRDUV01/";
    String sdn_parameter_urn "SDN:P01::IRRDUV01";
    String sdn_uom_name "MicroEinsteins per square metre per second";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UMES/";
    String sdn_uom_urn "SDN:P06::UMES";
    String sensor_manufacturer "Sea-Bird Scientific";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0013/";
    String sensor_manufacturer_urn "SDN:L35::MAN0013";
    String sensor_model "Sea-Bird SBE 16Plus V2 SEACAT C-T Recorder";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL0870/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL0870";
    String standard_name "visible waveband radiance and irradiance measurements in the water column";
    String units "MicroEinsteins per square metre per second";
  }
  VSRW_QC {
    Byte _FillValue 127;
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  PSAL_2 {
    String ancillary_variables "PSAL_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Other";
    String long_name "practical salinity";
    String sdn_parameter_name "Salinity of the water body by CTD";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/SSALST01/";
    String sdn_parameter_urn "SDN:P01::SSALST01";
    String sdn_uom_name "Dimensionless";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UUUU/";
    String sdn_uom_urn "SDN:P06::UUUU";
    String sensor_manufacturer "Sea-Bird Scientific";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0013/";
    String sensor_manufacturer_urn "SDN:L35::MAN0013";
    String sensor_model "Sea-Bird SBE 16Plus V2 SEACAT C-T Recorder";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL0870/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL0870";
    String standard_name "sea_water_salinity";
    String units "Dimensionless";
  }
  PSAL_2_QC {
    Byte _FillValue 127;
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String long_name "practical salinity quality flag";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  SVEL_2 {
    String ancillary_variables "SVEL_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Other";
    String long_name "sound velocity";
    String sdn_parameter_name "Sound velocity in the water body by computation from temperature and salinity by unspecified algorithm";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/SVELCV01/";
    String sdn_parameter_urn "SDN:P01::SVELCV01";
    String sdn_uom_name "Metres per second";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UVAA/";
    String sdn_uom_urn "SDN:P06::UVAA";
    String sensor_manufacturer "Sea-Bird Scientific";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0013/";
    String sensor_manufacturer_urn "SDN:L35::MAN0013";
    String sensor_model "Sea-Bird SBE 16Plus V2 SEACAT C-T Recorder";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL0870/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL0870";
    String standard_name "speed_of_sound_in_sea_water";
    String units "Metres per second";
  }
  SVEL_2_QC {
    Byte _FillValue 127;
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String long_name "sound velocity quality flag";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  TEMP_4 {
    String ancillary_variables "TEMP_4_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Temperature";
    String long_name "sea potential temperature";
    String sdn_parameter_name "Temperature of the water body";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/TEMPPR01/";
    String sdn_parameter_urn "SDN:P01::TEMPPR01";
    String sdn_uom_name "Degrees Celsius";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UPAA/";
    String sdn_uom_urn "SDN:P06::UPAA";
    String sensor_manufacturer "Sea-Bird Scientific";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0013/";
    String sensor_manufacturer_urn "SDN:L35::MAN0013";
    String sensor_model "Sea-Bird SBE 16Plus V2 SEACAT C-T Recorder";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL0870/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL0870";
    String standard_name "sea_water_potential_temperature";
    String units "Degrees Celsius";
  }
  TEMP_4_QC {
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String long_name "sea potential temperature quality flag";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  CNDC_3 {
    String ancillary_variables "CNDC_3_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Other";
    String long_name "electrical conductivity";
    String sdn_parameter_name "Electrical conductivity of the water body";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/CNDCZZ01/";
    String sdn_parameter_urn "SDN:P01::CNDCZZ01";
    String sdn_uom_name "Siemens per metre";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UECA/";
    String sdn_uom_urn "SDN:P06::UECA";
    String sensor_manufacturer "Sea-Bird Scientific";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0013/";
    String sensor_manufacturer_urn "SDN:L35::MAN0013";
    String sensor_model "Sea-Bird SBE 16Plus V2 SEACAT C-T Recorder";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL0870/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL0870";
    String standard_name "sea_water_electrical_conductivity";
    String units "Siemens per metre";
  }
  CNDC_3_QC {
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String long_name "electrical conductivity quality flag";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  PRES_3 {
    String ancillary_variables "PRES_3_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Pressure";
    String long_name "sea pressure";
    String sdn_parameter_name "Pressure (spatial coordinate) exerted by the water body by profiling pressure sensor and correction to read zero at sea level";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/PRESPR01/";
    String sdn_parameter_urn "SDN:P01::PRESPR01";
    String sdn_uom_name "Decibars";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UPDB/";
    String sdn_uom_urn "SDN:P06::UPDB";
    String sensor_manufacturer "Sea-Bird Scientific";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0013/";
    String sensor_manufacturer_urn "SDN:L35::MAN0013";
    String sensor_model "Sea-Bird SBE 16Plus V2 SEACAT C-T Recorder";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL0870/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL0870";
    String standard_name "sea_water_pressure";
    String units "Decibars";
  }
  PRES_3_QC {
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String long_name "sea pressure quality flag";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  DOXY_3 {
    String ancillary_variables "DOXY_3_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Other";
    String long_name "dissolved oxygen";
    String sdn_parameter_name "Concentration of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] by in-situ sensor";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/DOXYZZ01/";
    String sdn_parameter_urn "SDN:P01::DOXYZZ01";
    String sdn_uom_name "Millilitres per litre";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UMLL/";
    String sdn_uom_urn "SDN:P06::UMLL";
    String sensor_manufacturer "Sea-Bird Scientific";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0013/";
    String sensor_manufacturer_urn "SDN:L35::MAN0013";
    String sensor_model "Sea-Bird SBE 16Plus V2 SEACAT C-T Recorder";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL0870/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL0870";
    String standard_name "mole_concentration_of_dissolved_molecular_oxygen_in_sea_water";
    String units "Millilitres per litre";
  }
  DOXY_3_QC {
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String long_name "dissolved oxygen quality flag";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  PSAL_3 {
    String ancillary_variables "PSAL_3_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Other";
    String long_name "practical salinity";
    String sdn_parameter_name "Salinity of the water body by CTD";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/SSALST01/";
    String sdn_parameter_urn "SDN:P01::SSALST01";
    String sdn_uom_name "Dimensionless";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UUUU/";
    String sdn_uom_urn "SDN:P06::UUUU";
    String sensor_manufacturer "Sea-Bird Scientific";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0013/";
    String sensor_manufacturer_urn "SDN:L35::MAN0013";
    String sensor_model "Sea-Bird SBE 16Plus V2 SEACAT C-T Recorder";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL0870/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL0870";
    String standard_name "sea_water_salinity";
    String units "Dimensionless";
  }
  PSAL_3_QC {
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String long_name "practical salinity quality flag";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
  SVEL_3 {
    String ancillary_variables "SVEL_3_QC";
    String coordinates "TIME; DEPTH; LATITUDE; LONGITUDE";
    String data_mode "R";
    String ioos_category "Other";
    String long_name "sound velocity";
    String sdn_parameter_name "Sound velocity in the water body by computation from temperature and salinity by unspecified algorithm";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/SVELCV01/";
    String sdn_parameter_urn "SDN:P01::SVELCV01";
    String sdn_uom_name "Metres per second";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UVAA/";
    String sdn_uom_urn "SDN:P06::UVAA";
    String sensor_manufacturer "Sea-Bird Scientific";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0013/";
    String sensor_manufacturer_urn "SDN:L35::MAN0013";
    String sensor_model "Sea-Bird SBE 16Plus V2 SEACAT C-T Recorder";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL0870/";
    String sensor_SeaVoX_L22_code "SDN:L22::TOOL0870";
    String standard_name "speed_of_sound_in_sea_water";
    String units "Metres per second";
  }
  SVEL_3_QC {
    String _Unsigned "false";
    Byte colorBarMaximum 9;
    Byte colorBarMinimum 6;
    String conventions "Copernicus Marine In Situ reference table 2";
    String flag_meanings "no_qc_performed good_data probably_good_data bad_data_that_are_potentially_correctable bad_data value_changed value_below_detection nominal_value interpolated_value missing_value";
    Byte flag_values 0, 1, 2, 3, 4, 5, 6, 7, 8, 9;
    String ioos_category "Quality";
    String long_name "sound velocity quality flag";
    String standard_name "quality_flag";
    Byte valid_max 9;
    Byte valid_min 0;
  }
 }
  NC_GLOBAL {
    String cdm_data_type "TimeSeries";
    String cdm_timeseries_variables "time,depth,latitude,longitude";
    String Conventions "CF-1.6, Copernicus-InSituTAC-FormatManual-1.42, Copernicus-InSituTAC-SRD-1.5, Copernicus-InSituTAC-ParametersList-3.2.0, COARDS, ACDD-1.3, OceanSITES v1.4, SeaDataNet_1.0";
    String creator_email "nodc@ogs.it";
    String creator_type "institution";
    String creator_url "https://nodc.ogs.it";
    String data_mode "R";
    String data_type "OceanSITES time-series data";
    String date_created "44197";
    Float64 Easternmost_Easting 18.0824167;
    String featureType "TimeSeries";
    String format_version "1.4";
    Float64 geospatial_lat_max 41.5277;
    Float64 geospatial_lat_min 41.5277;
    String geospatial_lat_units "degrees_north";
    Float64 geospatial_lon_max 18.0824167;
    Float64 geospatial_lon_min 18.0824167;
    String geospatial_lon_units "degrees_east";
    Float64 geospatial_vertical_max 1185.0;
    Float64 geospatial_vertical_min -5.0;
    String geospatial_vertical_positive "down";
    String geospatial_vertical_units "m";
    String history 
"moored surface buoy
2024-03-28T08:49:20Z (source database)
2024-03-28T08:49:20Z https://nodc.ogs.it/erddap/tabledap/MAMBO1_TS.html";
    String infoUrl "https://nodc.ogs.it";
    String institution "National Institute of Oceanography and Applied Geophysics - OGS, Division of Oceanography";
    String institution_edmo_code "120";
    String keywords "AHGT, ALAT, ALKY, AYMD, CAPH, CDTA, CHUM, CNDC, CPWC, DOXY, EWSB, PCO2, PSAL, TEMP, TSED, VSRW";
    String keywords_vocabulary "SeaDataNet Parameter Discovery Vocabulary";
    String license "These data were collected and made freely available by the Copernicus project and the programs that contribute to it.";
    String network "OceanSITES";
    Float64 Northernmost_Northing 41.5277;
    String platform_code "MAMBO1";
    String principal_investigator "Fabio Brunetti";
    String principal_investigator_email "fbrunetti@ogs.it";
    String site_code "MAMBO1";
    String source "moored surface buoy";
    String source_platform_category_code "41";
    String sourceUrl "(source database)";
    Float64 Southernmost_Northing 41.5277;
    String standard_name_vocabulary "CF Standard Name Table v71";
    String summary "MAMBO1 timeSeries, NRT in situ Observations";
    String time_coverage_start "2021-01-01T00:00:00Z";
    String title "MAMBO1 timeSeries, NRT in situ Observations";
    String update_interval "void";
    Float64 Westernmost_Easting 18.0824167;
  }
}

 

Using tabledap to Request Data and Graphs from Tabular Datasets

tabledap lets you request a data subset, a graph, or a map from a tabular dataset (for example, buoy data), via a specially formed URL. tabledap uses the OPeNDAP (external link) Data Access Protocol (DAP) (external link) and its selection constraints (external link).

The URL specifies what you want: the dataset, a description of the graph or the subset of the data, and the file type for the response.

Tabledap request URLs must be in the form
https://coastwatch.pfeg.noaa.gov/erddap/tabledap/datasetID.fileType{?query}
For example,
https://coastwatch.pfeg.noaa.gov/erddap/tabledap/pmelTaoDySst.htmlTable?longitude,latitude,time,station,wmo_platform_code,T_25&time>=2015-05-23T12:00:00Z&time<=2015-05-31T12:00:00Z
Thus, the query is often a comma-separated list of desired variable names, followed by a collection of constraints (e.g., variable<value), each preceded by '&' (which is interpreted as "AND").

For details, see the tabledap Documentation.


 
ERDDAP, Version 2.18
Disclaimers | Privacy Policy | Contact